Street segments in Hurma that line up with the Boğaçayı corridor and its side channels fall inside officially mapped flood polygons; you can read the exact blocks on AFAD’s national flood‑hazard map and Antalya’s e‑İmar GIS at street zoom. Proof of storm‑drain upgrades is in ASAT’s as‑built drawings and acceptance (kabul) records. Proof of elevated ground‑floor slabs is in the approved architectural project attached to the building permit (yapı ruhsatı) and in the occupancy permit (yapı kullanım izin belgesi).
Locating flood‑prone streets in Hurma
Flood hazard in Turkey is mapped: the national program shows 10‑, 50‑, 100‑ and 500‑year inundation extents for rivers such as Boğaçayı in Konyaaltı, including Hurma on its northern bank. AFAD’s viewer displays flood polygons over address and street basemaps so you can see exactly which street segments fall within each return‑period zone. Search “Hurma Mahallesi, Konyaaltı, Antalya,” zoom to parcel level, and check whether a given street alignment intersects the 100‑year or 500‑year polygon along Boğaçayı or its tributaries. [1]
The Flood Regulation (Taşkın Yönetmeliği) sets the rules for preparing flood hazard maps and classifying extents by return period. In Antalya, the mapping covers the lower Boğaçayı reach before it discharges to the Mediterranean, which controls Hurma’s surface‑water risk. Judge street‑level risk by whether the street centerline or adjacent parcels lie inside the mapped polygon, not by distance, because the regulation treats risk as modeled inundation extent and depth. [2]
Antalya Metropolitan Municipality’s parcel‑based e‑İmar map shows planning layers and parcel identifiers (ada‑parsel) that you can cross‑check against AFAD’s polygons for a specific frontage. Locate the Hurma parcel by address, read the plan notes, and note any flood constraint recorded in the planning layers. Used together with AFAD’s hazard map, e‑İmar lets you name the exact street and building frontages inside mapped flood zones. [3][1]
If you need to confirm parcel geometry before comparing it with the flood layer, use the national Land Registry and Cadastre viewer (TKGM Parsel Sorgu) to retrieve official parcel boundaries and the ada‑parsel. Match that identifier in e‑İmar and then view the AFAD layer to document whether a frontage on a numbered street lies within a specific polygon. This uses official base maps for ownership and hazard and avoids reliance on informal lists of “risky streets.” [8][1]
Documents that prove upgraded storm drains in Hurma
Stormwater in Konyaaltı is planned, built and operated by the Antalya Water and Wastewater Administration (ASAT). If a Hurma street’s storm drains were upgraded—larger pipes, new catch basins, added manholes—the authoritative proof is the as‑built drawings and the temporary/final acceptance records for that investment held by ASAT. These files list pipe diameters, inverts, slopes, manhole locations and commissioning dates by street segment or project package. [4]
Public drainage works procured by a municipality undergo formal temporary (geçici) and final (kesin) acceptance under the General Specifications for Construction Works (Yapım İşleri Genel Şartnamesi). The signed minutes and attachments are legal evidence that the network was completed to the approved design and taken into service, with assets listed by location and specification. Together with the approved implementation project (uygulama projesi) and any revisions, these are the key documents a buyer should request for a specific Hurma street. [7]
Recent projects may appear on ASAT’s website as investment programs or project titles, and district units can confirm whether a given street block was included. For proof, though, rely on the approved design set, as‑built drawings, and acceptance records; these confirm pipe sizes, depths, and discharge routes toward Boğaçayı or the trunk system. [4][7]
Documents that prove elevated ground‑floor slabs
Ground‑floor slab elevation and plinth level (subasman kotu) are fixed in the architectural project attached to the building permit (yapı ruhsatı) under Zoning Law No. 3194 and the Regulation on Planned Areas (Planlı Alanlar İmar Yönetmeliği). The drawings show road grade (yol kotu), benchmarks, and the ground‑floor slab elevation (zemin kat döşeme kotu) in sections and elevations. These levels are approved by the municipality and control what may be built on the plot in Hurma. [6][5]
Compliance with those levels is certified when the municipality issues the occupancy permit (yapı kullanım izin belgesi, “iskan”) after construction. Issuance confirms that the building matches the approved project in key respects, including slab levels relative to road grade and benchmarks. A copy of the occupancy permit plus the permitted architectural drawings is therefore documentary evidence that the slabs were elevated as designed. Where needed, a licensed surveyor’s as‑built elevation certificate can be compared with the approved drawings for a specific entrance on a named street. [6][5]
Before permitting, Turkish technical rules also require a geological‑geotechnical and ground investigation report (zemin ve temel etüdü) for the plot or plan area. Ministry guidelines for ground and foundation studies evaluate groundwater and potential flood effects on foundations; resulting measures, including foundation elevation or waterproofing, can be noted in the project documentation. Requesting the ground study report for the Hurma parcel adds context on why a given plinth or slab elevation was chosen. [5]
A practical next step
Locate the frontage in AFAD’s hazard viewer and check whether the street centerline or parcels fall inside the Boğaçayı flood polygons. Pull the ada‑parsel from TKGM Parsel Sorgu, then open the same parcel in Antalya’s e‑İmar to read any flood‑related plan notes. For due diligence, ask ASAT for the as‑built drawings and the temporary/final acceptance minutes for any storm‑drain works on that street, and ask the seller or manager for the approved architectural drawings attached to the building permit plus the occupancy permit. For site‑specific interpretation of elevations and drainage capacity, hire a licensed Turkish architect or civil engineer in Antalya; this article is general information and does not replace professional advice.
Related Questions:
– How to read AFAD flood maps for a specific parcel in Antalya?
– Which permits and approvals control drainage connections in Konyaaltı?
– How do I verify a building’s occupancy permit and approved plans in Antalya?
– What counts as force majeure flood damage under Turkish condominium law?
References:
[1] AFAD (Disaster and Emergency Management Authority). “Türkiye Afet Tehlike Haritaları.” https://www.afad.gov.tr/turkiye-afet-tehlike-haritalari
[2] Resmi Gazete. “Taşkın Yönetmeliği.” https://www.resmigazete.gov.tr/eskiler/2014/06/20140615-3.htm
[3] Antalya Metropolitan Municipality. “e‑İmar Bilgi Sistemi.” https://imar.antalya.bel.tr
[4] ASAT General Directorate (Antalya Water and Wastewater Administration). “Kurumsal Bilgi ve Hizmetler.” https://www.asat.gov.tr
[5] Resmi Gazete. “Planlı Alanlar İmar Yönetmeliği (03.07.2017/30113).” https://www.resmigazete.gov.tr/eskiler/2017/07/20170703-5.htm
[6] Mevzuat Bilgi Sistemi. “3194 sayılı İmar Kanunu.” https://www.mevzuat.gov.tr/MevzuatMetin/1.5.3194.pdf
[7] Resmi Gazete. “Yapım İşleri Genel Şartnamesi (16.10.2019).” https://www.resmigazete.gov.tr/eskiler/2019/10/20191016-11.htm
[8] General Directorate of Land Registry and Cadastre (TKGM). “Parsel Sorgu.” https://parselsorgu.tkgm.gov.tr/
Disclaimer: This article is for informational purposes only and does not constitute legal, financial, or investment advice. Property law and tax rules in Turkey change frequently. Consult a licensed Turkish lawyer, accountant, or real estate professional before making any purchasing decision.
Related Articles
- On Beylikduzu’s Gurpinar cliffs, what erosion-control works and coastal construction limits apply to sea-view sites, and which reports should confirm slope stability?
- Around Atasehir Finans Merkezi, what weekday traffic peaks and rooftop HVAC plant noise levels should buyers test before choosing a mid- versus top-floor unit?
- In Sariyer’s Zekeriyakoy, how reliable is mains water pressure in summer and what wildfire evacuation routes and buffers should villa buyers confirm with the site and municipality?